DATA SHEET flox[on] | August 2020 | Page 1 Version 4.0 ■l| Proportional valve ■2| Outlet flange with thread connection ■3§ Inlet flange with thread connection ■4§ M8 Power supply ■5§ M12 Connector signal interface ■6^ Micro USB port ■7§ 3 LEDs operating mode iMENSiONS CONNECTION ASSIGNMENT M8 POWER SUPPLY Pin 1 24 VDC USB PORT The USB Port connects the flox]on] B with a PC. LED AND OPERATING MODUS Power In operation/run Error All information is provided in best conscience. Some clients may desire certain modifications which lead to results other than those found in this manual.
Katalog auf Seite 1 öffnen![data sheet flox[on] J - 2](https://img.directindustry.de/pdf/repository_di/118821/data-sheet-flox-on-j-924313_2m.jpg)
DATA SHEET flox[on] | August 2020 | Page 1 MASS FLOW CONTROLLER FEATURES Maximum flow Minimum flow Maximum operating pressure Regualtion ratio Device Accuracy Step response time (10% - 90%) Operating temperature FLOX[ON]J 5000 30 Nlmin-' Nlmin-' 16 1 : 50 1% Full Scale 7 or less from -10 to +60 GASES Calibration media standard: comp. air Process media (gas) comp. air, N2, Ar, CO2 ** In other cases a compatibility check is required. * In individual cases, if desired by the customer, the calibration can be made directly with the specific gas intended for use. EQiPMENT Connection M8 power...
Katalog auf Seite 2 öffnen![data sheet flox[on] J - 3](https://img.directindustry.de/pdf/repository_di/118821/data-sheet-flox-on-j-924313_3m.jpg)
FCTechnik M ass f low contro ller Data sheet flox[on] | August 2020 | Page 1 Version 4.0 USP p o rt and data e xc hang e You can get the software by asking for it (info@fc-technik.ch). It requires Windows. The software enables to operate the flox[on] B without any other process control. The software allows to: • to get all information about the device, • to see and to manipulate the calibration data, • to have a look at the actual operation and to overwrite the set point. Though the measuring cell does not require a recalibration for the rest of its lifetime it might be possible in very...
Katalog auf Seite 3 öffnen![data sheet flox[on] J - 4](https://img.directindustry.de/pdf/repository_di/118821/data-sheet-flox-on-j-924313_4m.jpg)
DATA SHEET flox[on] | August 2020 | Page 1 MASS FLOW CONTROLLER IMPORTANT NOTICES To ensure trouble-free Operation, the flox[on] J should be installed in a horizontal position. If installed vertically, the device could produce faulty measurements under certain conditions. The flox[on] J is maintenance-free even under harsh conditions. In case of a fault or failure of the measuring cell, please contact the service center. When delivered, the flox[on] J comes in secure transport packaging. It can be stored under dry conditions for up to two years before installation. The flox[on] J is...
Katalog auf Seite 4 öffnenAlle Kataloge und technischen Broschüren von FCTechnik - Gas Control Systems - flox[on] MFC
-
Datenblatt flox[on] B_neu
4 Seiten
-
data sheet flox[on] S
4 Seiten
-
Product Range
8 Seiten
-
Purge Plug Test Unit TST
4 Seiten
-
RH Lift Gas Tuyeres Test Unit
2 Seiten
-
Gas Mixing Module
2 Seiten
Archivierte Kataloge
-
flox[on] S
2 Seiten
-
flox[on] B
4 Seiten
-
Manual flox[on] S
8 Seiten
-
Manual flox[on] J
8 Seiten
-
Manual flox[on] B
8 Seiten
-
FCTechnik
3 Seiten
-
Gas Control
3 Seiten
-
flox[on] B new series
5 Seiten
-
flox[on] S500
2 Seiten
-
flox[on] B
2 Seiten