1. Kataloge
  2. HIOKI E.E. CORPORATION
  3. Stromzangen für AC/DC HIOKI 327x Series
video corpo

Stromzangen für AC/DC HIOKI 327x Series
1 /8Seiten

Stromzangen für AC/DC HIOKI 327x Series

Stromzangen für AC/DC HIOKI 327x Series
1 /8Seiten

Katalogauszüge

Stromzangen für AC/DC HIOKI 327x Series-1

CLAMP SENSOR Wide-band Models from DC to 100 MHz 3273-50 - 3276 CLAMP ON PROBES http://www.hioki.co.jp/ HIOKI company overview, new products, environmental considerations and other information are available on our website.

 Katalog auf Seite 1 öffnen
Stromzangen für AC/DC HIOKI 327x Series-2

1 3273-50 to 3276 CLAMP ON PROBE Because current measurement requires the insertion of a shunt or a CT, the task often becomes difficult due to breaks in the electrical path. The 3273-50 - 3276 CLAMP ON PROBEs only need to be connected directly into the BNC input on waveform observation equipment such as an oscilloscope or a recorder. Then simply clamp onto the conductor to be measured to easily observe current waveforms under a wide bandwidth and high sensitivity conditions. Important Characteristics 3273-50 3273-50 DC to 50 MHz I Square wave response I 1. Frequency response Input: 100 mAp-p...

 Katalog auf Seite 2 öffnen
Stromzangen für AC/DC HIOKI 327x Series-3

2 3273-50 to 3276 CLAMP ON PROBE I Waveform Example Features G High S/N ratio: ideal for measuring milliampere waveforms (Model 3273-50) G Capable of waveform monitoring from wide band and minute currents to large currents (Model 3274) G Permits waveform observation of large current of up to 500 Arms (Model 3275) G Wide-band waveform observations, from DC to 100 MHz (Model 3276) G Direct connection to BNC input of oscilloscope G Highly accurate current detection G Newly developed indium-antimony (InSb) thin-film Hall element G Simple overload protector prevents damage due to overheating G Easy...

 Katalog auf Seite 3 öffnen
Stromzangen für AC/DC HIOKI 327x Series-4

3 3273-50 to 3276 CLAMP ON PROBE 3273-50 3276 I 3273-50 / 3276 Specifications (accuracy is guaranteed at 23±3˚C [73±5˚F] after the power has been on for 30 minutes) 3273-50 3276 DC to 50 MHz (-3 dB) * See Fig. 1 on page 1. Frequency bandwidth DC to 100 MHz (-3 dB) * See Fig. 1 on page 1. Rise time 7 ns or less 3.5 ns or less Continuous maximum input range 30 Arms * Frequency derating see Fig. 2 on page 1. 30 Arms * Frequency derating see Fig. 2 on page 1. Maximum peak current value Non-continuous 50 Apeak Non-continuous 50 Apeak Output voltage rate 0.1 V/A 0.1 V/A Amplitude accuracy ±1.0% rdg....

 Katalog auf Seite 4 öffnen
Stromzangen für AC/DC HIOKI 327x Series-5

4 3273-50 to 3276 CLAMP ON PROBE 3274 3275 I 3274/3275 Specifications (accuracy is guaranteed at 23±3˚C [73±5˚F] after the power has been on for 30 minutes) 3274 3275 DC to 10 MHz (-3 dB) * See Fig. 1 on page 2. Frequency bandwidth DC to 2 MHz (-3 dB) * See Fig. 1 on page 2. Rise time 35 ns or less 175 ns or less Continuous maximum input range 150 Arms * Frequency derating see Fig. 2 on page 2. 500 Arms * Frequency derating see Fig. 2 on page 2. Maximum peak current value Non-continuous 300 Apeak 500 A peak at pulse width of ≤ 30 ms Non-continuous 700 Apeak Output voltage rate 0.01 V/A 0.01 V/A...

 Katalog auf Seite 5 öffnen
Stromzangen für AC/DC HIOKI 327x Series-6

5 9274/9276 CLAMP ON AC/DC SENSOR DC to MHz Range A wide range of current waveforms from DC to MHz can be observed at high precision. The 3270 is a DC/AC amplifier that can be connected to the 9274/9276 to enable current waveforms to be recorded and easily observed by connecting a recorder or oscilloscope. 3270 CURRENT MONITOR G Incorporates our custom-developed InSb thin-film Hall element The high degree of electron mobility in InSb makes it ideal for our highly sensitive thin-film Hall element. We have adapted these qualities for measuring a wide range of current, as well as for very low levels....

 Katalog auf Seite 6 öffnen
Stromzangen für AC/DC HIOKI 327x Series-7

6 9277 to 9279 UNIVERSAL CLAMP ON CT DC to 100 kHz (9277/9278) When used together with the 9555 SENSOR UNIT, current waveforms can be observed from DC to 100 kHz (Models 9277/9278). Controlled zero drift allows for stable, longduration measurements. 9279 I 9277 to 9279 UNIVERSAL CLAMP ON CT Specifications 9278 9277 9278 9279 Rated current (AC/DC) 20 A 200 A 500 A Output voltage (AC/DC) Accuracy (23 ± 3˚C) [73 ± 5˚F] DC and 45Hz to 66Hz Frequency characteristics (amplitude) (deviation from accuracy) Frequency characteristics (phase) (DC has no provision) Output resistance 2 V f.s. After demagnetization...

 Katalog auf Seite 7 öffnen
Stromzangen für AC/DC HIOKI 327x Series-8

7 I Rated current & Frequency characteristics AC/DC AC Wave Monitoring 500A 3275 : DC to 2MHz 9276 : DC to 1MHz 150A 3274 : DC to 10MHz 3273-50 : DC to 50MHz 30A 3276 : DC to 100MHz 9274 : DC to 10MHz 500A Level Monitoring 20A 9279 : DC to 20kHz 9272(20/200A) : 5Hz to 10kHz 200A 9271 : 5Hz to 50kHz 9278 : DC to 100kHz 9270 : 5Hz to 50kHz 20A 9277 : DC to 100kHz DC 1 10 100 1k 10k Frequency (Hz) 100k 1M 10M 100M ! WARNING 1. To avoid short circuits and electric shock accidents when using a clamp-on sensor, use only with power lines carrying voltages within the rating limit of the sensor. 2. To...

 Katalog auf Seite 8 öffnen

Alle Kataloge und technischen Broschüren von HIOKI E.E. CORPORATION

* Die Preise verstehen sich ohne MwSt., Versandkosten und Zollgebühren. Eventuelle Zusatzkosten für Installation oder Inbetriebnahme sind nicht enthalten. Es handelt sich um unverbindliche Preisangaben, die je nach Land, Kurs der Rohstoffe und Wechselkurs schwanken können.